The PMCD750 will flash a sequence of red and amber lights on the screen to indicate current status or if a fault exists. Cut out these cards for convenient
referencing of the on-screen codes.
Condition Priority Each block represents 0.2 seconds
Starts with red;
lamp is off
Door open 1 R R R
See footnote 1
Power supply fan failed 2 R Amber
DLP fan failed 3 R Amber R
350V failed 4 R R Amber
Optical engine failed 5
R R Amber R
Lamp failed 6
R R R R
Lamp off (wait, auto off)
2
7 R R Amber Amber
Wait (lamp off, cooling) 8
R R R R
Starts with
amber
Lamp off (lamp saver)
3
9 Amber Amber R
Lamp off (ready to turn on) 10
Amber Amber
Lamp striking (starting) 11
Amber Amber Amber
Lamp on, no alarms 12 Amber on continuously
R = Red To show the code, press
MONITOR button once.
1
With Priority 1-6, to turn lamp on, cycle off, and then on. If Auto Codes in the Miscellaneous menu is checked, events with Priority 1-5 start the
on-screen code automatically.
2
Lamp Saver turned lamp off; lamp is cooling and will turn on at end of cooling period.
3
A Lamp On command from the remote or from RS-232 commands will turn lamp on.
Condition Priority Each block represents 0.2 seconds
Starts with red;
lamp is off
Door open 1 R R R
See footnote 1
Power supply fan failed 2 R Amber
DLP fan failed 3 R Amber R
350V failed 4 R R Amber
Optical engine failed 5 R R Amber R
Lamp failed 6 R R R R
Lamp off (wait, auto off)
2
7 R R Amber Amber
Wait (lamp off, cooling) 8 R R R R
Starts with
amber
Lamp off (lamp saver)
3
9 Amber Amber R
Lamp off (ready to turn on) 10
Amber Amber
Lamp striking (starting) 11 Amber Amber Amber
Lamp on, no alarms 12
Amber on continuously
R = Red To show the code, press
MONITOR button once.
1
With Priority 1-6, to turn lamp on, cycle off, and then on. If Auto Codes in the Miscellaneous menu is checked, events with Priority 1-5 start the
on-screen code automatically.
2
Lamp Saver turned lamp off; lamp is cooling and will turn on at end of cooling period.
3
A Lamp On command from the remote or from RS-232 commands will turn lamp on.