Sharp PN-Y425 Car Video System User Manual


 
37
E
SETUP menu
Function
Command Direction
Parameter Reply Control/Response contents *
DATE/TIME SETTING DATE WR
AABBCCDDEE AABBCCDDEE
AA: Year, BB: Month, CC: Day, DD: Hour, EE: Minute
ID SETTING ID NO.SETTING IDST W
0-25
Sets the monitor’s ID number. (“0” means “no ID number”.)
R
0-25
Returns the monitor’s ID number.
ID NO. SETTING
(ONCE)
IDSL W
1-25
Sets a monitor ID number.
This ID number is only effective for the command immediately after this
command.
0
Clears the ID number if one has been designated.
ID NO. SETTING
(SUBSEQUENT)
IDLK W
1-25
Sets a monitor ID number.
This ID number is effective for the next and all subsequent commands after this
command.
0
Clears the ID number if one has been designated.
MULTI ENLARGE ENLG WR 0-1 0-1 0: OFF, 1: ON
ENLARGE MODE EMHV WR 11-55 11-55 1 x 1 (OFF) to 5 x 5 (“m x n” is expressed as “mn”, where m and n are the
numbers of monitors specied for the longest direction and the shortest direction
respectively.)
IMAGE POSITION
(M x N)
EPHV WR 11-55 11-55 Species values in the order of IMAGE POSITION IN LONGEST/ SHORTEST
DIRECTION.
BEZEL ADJUST BZCO WR 0-1 0-1 0: OFF, 1: ON
ENLARGE/
IMAGE POSITION
SETTING
ESHV WR XXYY XXYY XX: ENLARGE MODE (Same as EMHV), YY: IMAGE POSITION (Same as
EPHV)
THERMAL SENSOR SETTING STDR WR 0-1 0-1 0: LANDSCAPE, 1: PORTRAIT
ADJUSTMENT
LOCK
MONITOR
BUTTONS
ALCM WR 0-1, 3 0-1, 3 0: UNLOCKED, 1: LOCK ALL, 3: LOCK EXCEPT POWER
REMOTE
CONTROL
ALCR WR 0-3 0-3 0: UNLOCKED, 1: LOCK ALL, 2: LOCK EXCEPT VOLUME,
3: LOCK EXCEPT POWER
Others
Function
Command Direction
Parameter Reply Control/Response contents *
VOLUME VOLM WR 0-31 0-31
MUTE MUTE WR 0-1 0-1 0: OFF, 1: ON -
INFORMATION MODEL INF1 R Value
SERIAL NO SRNO R Value
TEMPERATURE SENSOR DSTA R 0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION ERRT R Value Returns the temperature at the temperature sensors in the following format.
[Sensor 1]
CAUSE OF LAST STANDBY MODE STCA W 0 Initialization
R 0 No detectable error has occurred
1 Standby mode by POWER button
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
20 Standby mode by OFF IF NO OPERATION setting
LAN SETUP USERNAME USER WR XXXXXXXX XXXXXXXX X: Eight characters or less; half-width alphanumeric characters, "-", and "_".
(The eld can be left blank, but spaces cannot be entered.)
PASSWORD PASS WR XXXXXXXX XXXXXXXX X: Eight characters or less; half-width alphanumeric characters, "-", and "_".
(The eld can be left blank, but spaces cannot be entered.)
TIPS
Some menu setting items do not have a command. Set with the remote control during installation.
Controlling the Monitor with a PC (RS-232C)