SMC Networks PFMV5 Stud Sensor User Manual


 
Safety Instructions
Flow Sensor
Instruction Manual
PFMV5
Series
URL http://www.smcworld.com
Specifications are subject to change without prior notice and any obligation
on the part of the manufacturer.
The descriptions of products shown in this document may be used by the
other companies as their trademarks.
© 2005 SMC Corporation All Rights Reserved
To facilitate recycling, this
manual is printed using
biodegradable soy ink, which
can easily be de-inked.
This manual is printed in the
"non-water system", which does
not output toxic liquid waste.
Thank you for purchasing the SMC PFMV5 Series Flow Sensor.
Please read this manual carefully before operating the flow sensor
and make sure you understand the flow sensor, its capabilities and
limitations.
Please keep this manual handy for future reference.
OPERATOR
This manual has been written for those who have knowledge of machinery
and apparatuses that use pneumatic equipment and have full knowledge of
assembly, operation and maintenance of such equipment.
Please read this manual carefully and understand it before assembling,
operating or providing maintenance service to the flow sensor.
Phone
AUSTRIA / (43) 2262-62 280 ITALY / (39) 02-92711
BELGIUM / (32) 3-355 1464 NETHERLANDS / (31) 20-531 8888
CZECH REP. / (420) 5-414 24611 NORWAY / (47) 67 12 90 20
DENMARK / (45) 70 25 29 00 POLAND / (48) 22-548 50 85
FINLAND / (358) 207 513 513 PORTUGAL / (351) 2 610 89 22
FRANCE / (33) 1-64 76 1000 SPAIN / (34) 945-18 4100
GERMANY / (49) 6103 4020 SWEDEN / (46) 8-603 0700
GREECE / (30) 1- 342 6076 SWITZERLAND / (41) 52-396 3131
HUNGARY / (36) 1-371 1343 TURKEY / (90) 212 221 1512
IRELAND / (353) 1-403 9000 UNITED KINGDOM / (44) 1908-56 3888
Precaution on Handling
Use UL approved product for direct current power supply.
1.Clamping voltage current circuit complies with UL508
Circuit which power supply if insulation transducer satisfying
following conditions
Max. voltage (No load) : 30Vrms (42.4V peak) or less
Max. current : (1) 8A or less (Including short circuit)
(2) When limited by the circuit
protector (fuse etc.) with the ratings in the table
below.
Voltage without load (V peak)
0 to 20 [V]
Over 20 [V] up to 30 [V]
Max. current rating (A)
5.0
100/peak voltage
2.Circuit (of class 2) which is of 30Vrms (42.4V peak) or less with the
power supply unit of class 2 complying with L1310 or transducer of
class 2 complying with UL1585.
The Flow Sensor have in after referred to as flow sensor and this
manual contain essential information for the protection of users and
others from possible injury and property damage and to ensure
correct handling.
Please check that you fully understand the definition of the following
messages (signs) before going on to read the text, and always follow
the instructions.
Read this manual and follow its instructions. Signal words such
as WARNING, CAUTION and NOTE, will be followed by
important safety information that must be carefully reviewed.
IMPORTANT MESSAGES
Indicates a potentially hazardous situation
which could result in death or serious injury
if you do not follow instructions.
Gives you helpful information.
Indicates a potentially hazardous situation
which if not avoided, may result in minor
injury or moderate injury.
Do not disassemble, modify (including change of printed circuit
board) or repair.
An injury or failure can result.
Do not operate outside of the specification.
Fire, malfunction or flow sensor damage can result.
Please use it after confirming the specification.
NOTE
Follow the instructions given below when handling the flow sensor.
Otherwise, the flow sensor may be damaged or may fail, thereby
resulting in malfunction.
Make sure to use a sensor by the specified voltage.
Make sure to use specified measurement flow and operating pressure.
Perform proper functional checks and leak tests after
maintenance.
Stop operation when an abnormality is observed such that the flow sensor
does not work properly or there is a leakage of fluid. Safety is not be assured
due to unexpected malfunction. When leakage occurred from other parts
except piping, the flow sensor might break. Cut off power supply and stop
supplying pressure. Don’t apply pressure at leaking condition.
To avoid fire and explosion, Do not use the product for
flammable fluid.
This flow sensor is designed for air. Only dry air, N
2
are applicable.
Do not operate in an environment of inflammable, explosive or
corrosive gas.
Fire or an explosion can result.
This flow
sensor is not an explosion proof type.
Do not use this product near by a place where static electricity
is a problem.
Otherwise it can cause failure or malfunction of a system.
These instructions must be followed while in maintenance ;
Turn off the power supply, stop the supplied air, exhaust the
residual pressure and verify the release of air before
performing maintenance.
Otherwise it can cause injury.