16
Motor will not run Check valve restricted•
Motor overload protection •
switch has tripped
Extension cord is wrong •
length or gauge
Loose electrical connections•
Possible defective motor or •
starting capacitor
Paint spray on internal motor •
parts.
Fuse blown, circuit breaker •
tripped
Tank pressure exceeds pres-•
sure switch cut-in pressure
Pressure release valve on •
pressure switch has not un-
loaded head pressure
Remove, clean or replace•
See Motor Overload under Features.•
Check proper gauge wire and cord •
length. See Extension Cords under pg. 9.
Contact a Bosch factory service center •
or a Bosch authorized service center.
Contact a Bosch factory service center •
or a Bosch authorized service center.
Contact a Bosch factory service center •
or a Bosch authorized service center.
Do not operate the compressor in the
paint spray area. See flammable vapor
warning.
1. Check fuse box for blown fuse and replace
as necessary. Reset circuit breaker. Do
not use a fuse or circuit breaker with higher
rating than that specied for your particular
branch circuit.
2. Check for proper fuse. Use only a time de-
lay fuse.
3. Check for low voltage conditions and/or
proper extension cord.
4. Disconnect the other electrical appliances
from circuit or operate the compressor on
its own branch circuit.
Motor will start automatically when tank •
pressure drops below cut-in pressure of
pressure switch.
Set the On/Off switch to OFF. If the •
valve does not open, replace switch.
Contact a Bosch factory service center
or a Bosch authorized service center.
trouble sHootInG