1st Position
2nd Position 50 70 50 70 70 70 40 85
3rd Position 61 79 67 83 74 89 70 101
4th Position 68 83 75 90 84 97 84 110
5th Position 74 87 85 96 91 104 95 117
6th Position 79 90 91 101 99 110 103 125
7th Position 82 93 97 104 104 115 109 130
8th Position 85 95 104 107 108 118 115 135
(Factory Set)
9th Position 89 100 117 111 115 124 124 141
10th Position 98 105 134 121 128 136 140 153
11th Position 111 115 138 133 149 151 165 172
Setting of limiter
The fi rst position of the Rotational Limit Stop (the Limiter) is that position that restricts the rotation of the stem the
most and is at the maximum counterclockwise setting. According to industry standards, the maximum allowable
temperature of the water exiting from the valve is 120°F. This temperature may vary in your local area. The Rota-
tional Limit Stop may need to be readjusted if the inlet water temperature changes. For instance, during the winter,
the cold water temperature is colder than it is during the summer which could result in varying outlet temperatures.
Typical temperature for a comfortable bath or shower is between 90°-110°F.
SHUT OFF ZONE: NO FLOW APPROXIMATELY 0-20 DEGREES OF HANDLE ROTATION
Cold Hot
70°F 160°F
Cold Hot
85°F 180°F
Cold Hot
40°F 180°F
Cold Hot
50°F 160°F
Cold Hot
70°F 140°F
Cold Hot
50°F 140°F
Cold Hot
70°F 120°F
Cold Hot
50°F 120°F
MIX TEMPERATURE-VS-POSITION OF ROTATIONAL LIMIT STOP
APPROXIMATE MIX TEMPERATURE (°F) WITH VARYING INLET TEMPERATURES
WARNING: This is a guide to help you set the Rotational Limit Stop. This is only a guide and should be verifi ed by
following the instructions on setting the rotational limit stop given in this installation and instruction sheet.
Setting of limiter
©1995 Jacuzzi Whirlpool Bath G570000 D 12/06 Page 5