Kathrein VOS 40/F Car Amplifier User Manual


 
936.2763/C/0703/4.4e/ZWT
Do not touch live parts
The power plug must be easily operable as the means of cutting
power to the ampli er, meaning the wall outlet must be close to
the ampli er and easily accessible
The power must be cut when installing or removing the ampli er
The ampli er must not be operated without the standard power
supply protective cover tted. The cover must be closed
Basic safety precautions
Caution!
The ampli er supply voltage is 230 V AC
and is dangerous on directcontact!
Interstage
at
-6dB
Equalisation
(VOS 40/F)
Gain
Jumper for test
socket
Return path output
After measurement:
switch off X7!
Electronic equipment is not domestic waste - in accordance with directive 2002/96/EC
OF THE EUROPEAN PARLIAMENT AND THE COUNCIL dated 27
th
January 2003 on
used electrical and electronic appliances, it must be disposed of properly.
At the end of its service life, take this unit for disposal to an appropriate of cial collection
point.
Internet: http://www.kathrein.de
KATHREIN-Werke KG • Anton-Kathrein-Straße 1 - 3 • P.O. Box 100 444 • 83004 Rosenheim • GERMANY • phone +49 8031 184-0 • Fax +49 8031 184-306
Equalisation
VOS 30/F: 30 dB 24 dB
VOS 40/F: 40 dB 34 dB
Controls and plug-in modules
(after removal of the housing cover)
Attenuation
Off On
Return path module (option)
The 0 dB bridge circuits (o)
must be removed rst!
Note:
Input
Output
Test socket
return path output
-20 db
Test socket
output
-20 db