Pelco C572M Car Satellite Radio System User Manual


 
PHYSICAL INSTALLATION CM9760-SAT 1-1
SECTION 1 PHYSICAL INSTALLATION
1.0 COM CONNECTION ....................................................... 1-1
9760 SIDE
CC1 to Wall Block ............................................................. 1-2
SAT SIDE
Wall Block to SAT ............................................................. 1-2
2.0 VIDEO TIE-LINES ........................................................... 1-2
9760 SIDE ........................................................................... 1-2
SAT SIDE ............................................................................. 1-2
**
SATs
received in a system order are
assigned connection locations that are
found on your included port assignment
sheet(s). These indicate the CC1 Sercom
port to connect your
SAT
to.
If you are adding the
SAT
to an existing
system, you must
FIRST
do an across-
the-board check of your system software
to ensure it is compatible with the version
levels required for satellite operation. The
information box on the first page of this
manual (
9760 Operational Param-
eters
) indicates the minimum version
levels of software required for satellite op-
erations. If necessary, upgrade your as-
sociated system and peripheral software.
3.0 ADDITIONAL SAT CONNECTIONS ............................ 1-3
Local Monitor ................................................................. 1-3
Link Cameras ....................................................................... 1-3
Looping Video Inputs ..................................................... 1-3
Receivers ....................................................................... 1-4
Alarms ............................................................................ 1-4
Auxs ............................................................................... 1-5
Local Keypads ............................................................... 1-5
Figure 1-1
CC1 to SAT Interface
Figure 1-2
Alternate CC1 to SAT Interface
1.0 COM CONNECTION
The COM connection between the CM9760-CC1 and the CM9760-SAT runs from an available sercom port** on the rear of the CC1 to appropriate
pinouts located on the wiring plug for COM 2 on the SAT. A physical disparity exists between the RJ-45 connector on the CC1 SIDE and the 12-PIN
wiring plug on the SAT SIDE. An intervening wall block can be used (normally placed at the SAT SIDE) to facilitate the connection.***
NOTE:
The RJ-45 wall block, represented in Fig-
ure 1-1, can be obtained by ordering a Pelco
“KBDKIT”. In many cases, however, an
SAT
sys-
tem order will include several key-
pads in order to accommodate
more than one operator on
the
SAT SIDE
. Multiple key-
pads are wired via the re-
mote- keyboard, wiring plug.
In order to provide power to
the keyboard, a KBDKIT,
which includes a transformer,
is required, as power is not
provided at the remote port
itself. The kit, however, con-
tains two wall blocks. Only
one wall block is needed to
wire the keypad. The “spare”
could be used here.
***
An alternate method
is to strip the 8-conductor,
flat communication cable
to expose the necessary
communication wires and
then wire directly to the
wall plug, eliminating the
need for the wall block
(see below).