Phoenix Gold • www.phoenixgold.com
Amplier Owner’s Manual
System tuning
TROUBLESHOOTING
1. Install all system fuses.
2. Set the amplier’s input sensitivity controls to their minimum positions
(full counterclockwise).
3. Set all amplier crossover switches according to your system’s design.
4. Make preliminary adjustments to the crossover frequency, usually 80Hz
is good starting point for high and low pass. It may be necessary to ne
tune the crossover frequency later for the best overall sound quality.
5. If using a Remote Subwoofer Level Control, set it to maximum (full
clockwise).
6. Turn the headunit on with the volume set to minimum.
7. Visually check the amplier’s has turned on by the power LED.
8. Check the condition of all other components to make sure they are
powered up.
9. Set the headunit’s tone controls, balance, and fader to the center (at)
position. Turn o any loudness or other signal processing features.
10. Set the volume control of the headunit to 3/4 of maximum volume. Play
music you typically listen to through the system.
11. Turn up the sensitivity or input level control on the amplier until the
speakers reach maximum undistorted output.
12. Repeat sensitivity level adjustments for all other ampliers.
13. Reduce the headunit’s volume to a comfortable level.
14. Listen to various musical selections to check overall system balance.
Compare front to rear, midbass to midrange, etc. If one speaker set is
too loud compared to another, then its level must be lowered to blend
correctly with the other speakers.
Note: For subwoofers controlled by the Remote level control, keep the
level setting from step 11 or 12. Use the control to blend subwoofers
with the rest of the system. The correct subwoofer volume will change
depending on road noise and dierences in recordings.
15. Fine tune crossover frequencies to achieve the smoothest possible
blending of each speaker set.
16. Adjust the Bass Equalization Controls on the amplier, headunit or
processor upstream if necessary to increase output.
Note: Use these controls sparingly. Every 3dB of boost requires double the
power at 45Hz. If your subwoofer system requires a lot of boost to sound
good, there may be a problem. Look for out-of-phase woofers, a leaking
subwoofer box, or incorrect box size.
17. With all levels set correctly, the system will reach overall maximum
undistorted output at the volume level set in step 10.
NO POwER:
Check voltage at the amplier with a DMM (volt meter), +12v and R
(with head unit on) the voltage should register between 11.5V and
14.4V when using the attached ground lead of the amplier. Check
fuse at the battery. Use a meter to verify connection from one end
of the fuse to the other, breaks may not always be visible. If the fuse
is blown, check the power wire and also the amplier for a short. If
the short is in the amplier itself, see your Phoenix Gold dealer. If no
short is present, replace the fuse.
POwER wITHOUT SOUND:
Turn the amplier o and check all input and output signal cables
and power connections. Check the speakers for shorts with a DMM
(volt meter) or by connecting them to another audio source. After
making sure everything is correct, turn the amplier on again.
POwER, NO SOUND, PROTECT LED LIT:
The red PROTECT LED lights when the amplier shuts down for
either thermal or over-current protection. A high internal amplier
operating temperature will trigger thermal shutdown: after it
cools about 5°C, the amplier will restart. A shorted speaker lead
or operation into unusually low impedance loads will trigger over-
current shutdown: cycle power at the amplier R terminal to restore
operation. Check for shorted speaker wiring or damaged speakers
or crossover systems if over-current shutdown occurs.
NO SOUND FROM ONE OR MORE CHANNELS:
Check the balance control in the head unit. Check speaker
connections. Check signal input connection. Very low output: Check
your head unit’s fader control or the amplier’s input sensitivity
level. Make sure subsonic frequency control is not set too high and
LP frequency control is not set too low at the same time.
FREQUENT AMPLIFIER SHUTDOwN wITH AUTOMATIC
RECOVERY:
This indicates chronic amplier thermal shutdown because
of operation at consistently high internal temperatures. High
operating temperature can be caused by inadequate ventilation.
Make sure you are not running a lower than recommend
impedance. Also check for damaged speakers or passive crossover
systems. Finally, chronic thermal shutdown may result from
otherwise normal operation of the amplier at elevated output
power levels, which can be resolved by providing additional
amplier cooling, installing a higher-power amplier, or reducing
amplier output level.
POwER CYCLES ON/OFF QUICKLY:
The power indicator going o repeatedly when the audio system is
on. Check the amplier’s connection to the battery. Check battery
voltage. If low, recharge or replace the battery. Check all ground
connections.