9
WM–700796
7. ELECTRICAL DATA
● Electrical Characteristics
KHS1822 / CH1822
Remarks: Rating conditions are:
Cooling: Outside air temperature 95°F DB/75°F WB
Indoor unit entering air temperature 80°F DB/67°F WB
Heating: Outside air temperature 47°F DB/43°F WB
Indoor unit entering air temperature 70°F WB
Performance at
Indoor Unit Outdoor Unit Complete Unit
230/208V – 1ø – 60Hz
Fan Motor Max. Heat Fan Motor Compressor Heat-pump Max. Heat
Cooling
Rating
A 0.40 / 0.40 — 0.47 / 0.47 7.13 / 7.73 8.0 / 8.6 —
Conditions
W 90 / 81 — 105 / 95 1,595 / 1,564 1,790 / 1,740 —
Heating
Rating
A 0.40 / 0.40 7.8 / 7.1 0.47 / 0.47 7.13 / 7.73 8.0 / 8.6 15.8 / 15.7
Conditions
W 90 / 81 1,800 / 1,470 105 / 95 1.595 / 1.574 1,790 / 1,750 3,590 / 3,220
Locked-Rotor Amperes A 0.45 / 0.40 — 0.71 / 0.64 52 — —