I - 85
SM830082
1
2
3
4
5
1. Specifications
1-9 Performance Charts
● Cooling Characteristics
(2) Operating Pressure
11
11
1 Indoor Unit: 36 Type Outdoor Unit: CH3642
• High Pressure
High pressure characteristics versus outdoor ambient temperature and indoor temperature.
(Indoor relative humidity: 50%, Indoor fan speed: High)
230V / 208V
• Low Pressure
Low pressure characteristics versus outdoor ambient temperature and indoor temperature.
(Indoor relative humidity: 50%, Indoor fan speed: High)
230V / 208V
1459_X_S
Discharge pressure (psig)
260
280
300
320
180
160
140
200
220
240
59 68 77 86 95 104
(15) (20) (25) (30) (35) (40)
Outdoor ambient temp. °F (°C)
Indoor
temp.
°F (°C)
Outdoor fan speed
Low
High
70 (21)
85 (30)
80 (27)
75 (24)
1460_X_S
Suction pressure (psig)
100
60
50
40
70
80
90
59 68 77 86 95 104
(15) (20) (25) (30) (35) (40)
Outdoor ambient temp. °F (°C)
Indoor
temp.
°F (°C)
Outdoor fan speed
Low
High
85 (30)
80 (27)
70 (21)
75 (24)