19
Servo OFF
Tracking servo ON
Recording mode OFF
CLV normal mode
Tracking offset cancel OFF
Groove
Low reflection
CLV A
CLV UNLOCK
Contents
When Lit When Off
Display
Servo ON
Tracking servo OFF
Recording mode ON
CLV low speed mode
ABCD adjustment completed
Tracking offset cancel ON
Tracking auto gain OK
Focus auto gain OK
Pit
High reflection
CLV S
CLV LOCK
4-8. MEANINGS OF OTHER DISPLAYS
G
X
REC
SYNC
L.SYNC
OVER
B/1
A-/REP
TRACK/(LP) 4/Calendar frame
DISC/LP2
SLEEP/SHUF
MONO
4-9. AUTOMATIC SELF-DIAGNOSIS FUNCTION
This test mode performs CREC and CPLAY automatically for mainly checking the characteristics of the optical pick-up.
To perform this test mode, the laser power must first be checked.
Perform AUTO CHECK after the laser power check and Iop check.
Procedure
1. Press the YES button. If LDPWR is displayed, it means that the laser power check has not been performed. In this case,
perform the laser power check and Iop compare, and then repeat from step 1.
2. If a disc is in the mechanical deck, it will be ejected forcibly.
DISC IN will be displayed in this case. Load a test disc (MDW-74/GA-1) which can be recorded.
3. If a disk is loaded at step 2, the check will start automatically.
4. When XX CHECK is displayed, the item corresponding to XX will be performed.
When 06 CHECK completes, the disc loaded at step 2 will be ejected. DISC IN will be displayed. Load the check disc (MD) TDYS-1.
5. When the disc is loaded in step 4, the check will automatically be resumed from 07 CHECK.
6. After completing to test item 12, check OK or NG will be displayed. If all items are OK, CHECK ALL OK will be displayed. If any item
is NG, it will be displayed as NG:xxxx.
When CHECK ALL OK is displayed, it means that the optical pick-up is normal. Check the operations of the other spindle motor, thread
motor, etc.
When displayed as NG:xxxx, it means that the optical pick-up is faulty. In this case, replace the optical pick-up.
4-10. INFORMATION
Display the software version.
Procedure
1. If displayed as INFORMATION, press the YES button.
2. The software version will be displayed.
3. Press the MENW/NO button to end this mode.
4-11. WHEN MEMORY NG IS DISPLAYED
If the nonvolatile memory data is abnormal, E001/MEMORY NG will be displayed so that the MD deck does not continue operations.
In this case, set the test mode promptly and perform the following procedure.
Procedure
1. Set the test mode. (Refer to 4-2.)
2. Normally a message for selecting the test mode will be displayed. However if the nonvolatile memory is abnormal, the following will be
displayed. INIT EEP?
3. Press the STOP button and EJECT button together.
4. Rotate the AMS knob and select MDM-7A.
5. Press the AMS knob. If the nonvolatile memory is successfully overwritten, the normal test mode will be set and a message to select the
test mode will be displayed.