Specifications
Controller
Microprocessor-based, user selectable control modes
Heat and cool auto-tune for control outputs
Universal input 1, auxiliary input 2, 4 outputs
Control outputs user selectable as on-off, P, PI, PID
Input sample period; Single input 10Hz (100 ms), dual
input 5Hz (200 ms) adjustable digital filter
Display update; 2Hz (500 ms), adjustable digital filter
Output update; burst, 0.1 to 999.9 seconds
Input/Output/Communication isolation
Displayed in °C, °F, or process units
Operator Interface
Dual 4-digit LED displays: upper 10.2 mm (0.4 in.),
lower 6.2 mm (0.244 in.)
Advance, Up Arrow, Down Arrow, Infinity tactile keys
Standard Conditions For Specifications
Ambient temperature 25°C/77°F ±3°C, rated line
voltage, 50 to 60Hz, 0 to 90 percent RH
non-condensing, 15 minute warm-up
Universal Input 1
Thermocouple
Type J, K, T, N, C (W5), E, Pt 2, D (W3), B, R, S
thermocouple types
>20M
input impedance
Maximum 20
source resistance
30µA open detection bias
RTD
2- or 3-wire platinum, 100
JIS and DIN curves
Whole or tenth degree indication
150µA nominal RTD excitation current
Process
Range selectable: 0-10VÎ(dc), 0-5VÎ(dc),
1-5V
Î(dc), 0-20mA, 4-20mA,
Voltage input impedance 20k
Current input impedance 100
Minimum current source resistance 1M
Input resolution 50,000 bits (approx.) at full scale
mV input impedance 20M
Input 2
Event Input
Contact or voltage
20K
input impedance
Voltage input: event high state 3 to 36V
Î(dc),
event low state 0 to 2V
Î(dc)
Resistance/contact input: event high state > 23k
,
event low state 0 to 2k
Remote Set Point Input: mA or VDC Range Selectable
Voltage input impedance 20k
Current input impedance 100
Output Types
Open Collector/Switched DC
Open collector configuration:
Maximum voltage 42V
Î(dc)
Maximum current 200mA
Maximum “on” resistance 1.1
Maximum offstate leakage current 100µA
Switched dc configuration:
Switched dc supply voltage 22 to 28V
Î(dc)
dc supply current limited to 30mA
Solid State Relay
Optically isolated
Zero cross switched
Without contact suppression
Minimum load current 0.5mA rms
Maximum current 0.5A rms at 20 to 280V
Å(ac)
Maximum offstate leakage current 10µA rms
For resistive loads only, must use RC suppression for
inductive loads
Electromechanical Relay
Form C contact configuration
Minimum load current 10mA @ 5V
Î(dc)
Rated resistive and inductive loads: 2A @ 250V
Å(ac)
or 30V
Î(dc) maximum
Electrical life 100,000 cycles at rated current
For resistive loads only, must use RC suppression for
inductive loads
Process
Range selectable: 0-20mA, 4-20mA, 0-5VÎ(dc),
1-5V
Î(dc), 0-10VÎ(dc)
Reverse or direct acting
0 to 10V
Î(dc) voltage output into 1000 minimum load
resistance
0 to 20mA current output into 800
maximum load
resistance
Resolution:
dc ranges = 2.5mV nominal
mA ranges = 5µA nominal
Calibration accuracy:
dc ranges = ±15mV
mA ranges = ±30µA
Temperature stability 100ppm/°C
Retransmit
Range selectable: 0-20mA, 4-20mA, 0-5VÎ(dc),
1-5V
Î(dc), 0-10VÎ(dc)
0 to 10V
Î(dc) voltage output into a 1,000 minimum
load resistance
0 to 20mA current output into an 800
maximum load
resistance
Resolution:
dc ranges = 2.5mV nominal
mA ranges = 5µA nominal
Calibration accuracy:
dc ranges = ±15mV
mA ranges = ±30µA
Temperature stability 100ppm/°C