Note: The expectation is that a 2-3 page extraction from a larger manual will be submitted as
evidence for each of the tasks above. Based on this information, AT&T may elect to conduct a
more thorough review by accessing the information as listed below
7.13.2 List of Documentation
Forward a list of all documentation that will be provided to AT&T for the planned deployment of
the equipment (e.g., full document number, title and revision number for planning, installation,
operations, etc.) and instructions on how AT&T can access these documents at this time (e.g.,
Public Website, Restricted client portal.)
.
7.13.3 Provide a list sites where AT&T can gain access to the above documents today.
(i.e. Public Website, Restricted client portal.)
8 Other interconnection requirements
8.1 Equipment lighting
If NE includes integrated lighting system, the system shall meet the lighting and illumination
requirements in ATT-TP-76400.
8.2 Test (Streaker) Cards
Network Transport Elements shall have test cards (e.g., streaker) to enable verification of the
network element hardware and the continuity of cabling, through the backplane, to the point of
termination such as DSX panels or frames.
The test card or cards shall not:
• require the shelf to be powered for such testing.
• interrupt existing service on any other slot.
The test card or cards shall:
• Provide metallic access to each backplane terminating conductor via an appropriate
connector Bantam for DS1, including timing inputs, 440 for DS-3, STS-1 and E-3 Facilitate
electrical signal insertion and transmission toward the drop; especially for DS1 or DS3 signals.
• Facilitate optical signal insertion and transmission for continuity checking of optical
jumpers that would, when such active Plug-In were installed, interconnect rear terminated Plug-
Ins utilizing shelf backplane(s) optical connectors/barrels using SC or LC connectors.
Note: Test Set connections on face of Plug-In shall conform to AT&T standard connectors.