CBP Tank Calibration (continued)
Adjust the Liquid Flow:
1. Disconnect the liquid treatment tubing
from the elbow tting under the HCBT inlet hopper and
place it in a calibrated beaker to measure the liquid
seed treatment output.
3. Hold the HCBT Pump switch
to MANUAL. Measure the treatment output after one
minute. Release the Pump switch to turn the pump
OFF. Record your volume measurement. Pour the
liquid seed treatment back into the premix tank.
CBP-30 Tank Metering Ball Valve
HCBT Pump Control Switch
4. If you do not get the desired volume in one minute,
change the valve setting up or down and repeat step 3
above. Repeat this process until the output of the
liquid seed treatment product is correct. When you
liquid output per minute is correct, the calibration
process is complete.
Continued...
1/2” OD Chemical Pump Port
2. Turn the HCBT Pump AGITATION switch
to ON.
HCBT AGITATOR Control Switch
HOLD