7
36″ COOKTOPS/DOWNDRAFT UNITS
JVB64, JVB65, JVB96
Figure 2
Overall Cutout Dimensions
Figure 3
Cutout for Vent
Figure 1
Overall Cooktop Dimensions
1
2
3
NOTE: AGAINST-THE-WALL INSTALLATIONS ARE LIMITED DUE TO DIMENSION REQUIREMENTS.
REFER TO DETAILS BELOW.
PLANNING INSTALLATION (Note: 26″ deep cabinets required) PREPARING CUTOUT
A B C B&C D I E F G H
(Figure 1) (Figure 1) (Figure 1) (Figure 1) (Figure 3*) (Figure 2) (Figure 2) (Figure 2) (Figure 3) (Figure 3)
Min. Setback— Downdraft
Cooktop Cooktop Depth Front Edge Min. Req’d. Cooktop Cooktop Add’l Depth Cutout Width
Overall Overall Vent Cktop + Cntrtop to Front Inside Cabinet Cutout Cutout Req’d for Req’d from
Model No. Width Depth Depth D.D. Vent Edge of Cutout Clearance Width Depth Downdraft Centerline
JP622
JP623
35-1/2″ 21″ 2″ 23″ 3-1/4″ 22″ 33-7/8″ 19-1/16″ 2-7/8″ 33-1/16″
JP681 35-1/2″ 21″ 2″ 23″ 3-1/4″ 21-9/16″ 33-7/8″ 19-1/16″ 2-7/8″ 33-1/16″
JP692
JP693
35-1/2″ 20-3/4″ 2″ 22-3/4″ 2″ 22-7/16″ 34-5/8″ 19-15/16″ 2-5/16″ 33-1/16″
JGP630
JGP631
35-1/2″ 21″ 2″ 23″ 3-1/4″ 22″ 33-7/8″ 19-1/16″ 2-7/8″ 33-1/16″
*Required to maintain UL or AGA approvals.