Error Codes and Troubleshooting
JobJob
Job
LogLog
Log
The job log le name is 2–JOB.CSV and is stored
in the DATAxxxx folder.
The job log maintains a record of data points
based on the USB Log Frequency dened
in the Setup screens. The ADM stores the
last 237,000 data points for download. See
Setup - Advanced Screen 3 — USB, page 35, for
information on setting the Download Depth and USB
Log Frequency.
• Data point date
• Data point time
• A side temperature
• B side temperature
• Hose temperature
• A side temperature setpoint
• B side temperature setpoint
• Hose temperature setpoint
• Pressure A
• Pressure B
• A side inlet pressure (Elite only)
• B side inlet pressure (Elite only)
• A side inlet temperature (Elite only)
• B side inlet temperature (Elite only)
• Inlet pressure setpoint
• System lifetime pump cycle counts
• Usage Volume (manual)
• Pressure, volume, and temperature units
• Job name/number
DailyDaily
Daily
LogLog
Log
The daily log le name is 3–DAILY.CSV and is stored
in the DATAxxxx folder.
The daily log maintains a record of the total cycle
and volume sprayed on any day that the system is
powered up. The volume units will be the same units
that were used in the Job Log.
The following data is stored in this le:
• Date that material was sprayed
• Time — unused column
• Total pump cycle count for day
• Total volume sprayed for day
SystemSystem
System
SoftwareSoftware
Software
LogLog
Log
The system software le name is 4–SYSTEM.CSV
and is stored in the DATAxxxx folder.
The system software log lists the following:
• Date log was created
• Time log was created
• Component name
• Software version loaded on the above component
BlackboxBlackbox
Blackbox
LogLog
Log
FileFile
File
The black box le name is 5–BLACKB.CSV and is
stored in the DATAxxxx folder.
The Blackbox log maintains a record of how the
system runs and the features that are used. This log
will help Graco troubleshoot system errors.
DiagnosticsDiagnostics
Diagnostics
LogLog
Log
FileFile
File
The diagnostics le name is 6–DIAGNO.CSV and is
stored in the DATAxxxx folder.
The Diagnostics log maintains a record of how the
system runs and the features that are used. This log
will help Graco troubleshoot system errors.
SystemSystem
System
CongurationConguration
Conguration
SettingsSettings
Settings
The system conguration settings le name is
SETTINGS.TXT and is stored in the DOWNLOAD
folder.
A system conguration settings le automatically
downloads each time a USB ash drive is inserted
into the ADM. Use this le to back up system
settings for future recovery or to easily replicate
settings across multiple systems. Refer to the
Upload Procedure, page 63 for instructions on how
to use this le.
62334945B