9.2. Measurement Procedure
9.2.1. Video Output Level
MEASURING SYSTEM System 1
PROCEDURE
TEST CONDITIONS Refer to “MEASUREMENT CONDITIONS”
1. Shoot the gray scale chart, and zoom WIDE or TELE to fit the chart
to the monitor
2. Measure the video output level on the waveform monitor
(Before the above measurement, Measure the SYNC and
BURST levels)
SPECIFICATION:
Video Level A
100 ± 10 IRE
Sync Level B
40 ± 5 IRE
Burst Level C
40 ± 5 IRE
20