Install to Fit Your Application
NOTE: Priortoinstalling,seriousconsiderationmustbetakentoinsurethisventilationsystemwill
operate properly if integrated with any other type of mechanical system, i.e. a forced air system,
oranairhandlingunit.Toinsureproperoperation&compatibilitiesofbothsystem,itisrequired
thattheairflowsofventilationsystemsbebalanced,byfollowingtheproceduresfoundinthis
manual.
Limitations:Theproductisforresidentialapplicationsonly.Mustbeinstalledinaccordancewithall
nationalandlocalregulations,buildingandsafetycodes.Flexductisrecommendedforconnectingto
theERV/HRVcollarstoreducevibrationnoise.
M24745
Electrical Requirements:
120 VAC outlet. Ground fault
interrupter (GFI) and dedicated
circuit recommended.
This application uses a devoted duct system for the supply and the exhausting of stale air
accumulated in the home.
Honeywellrecommendsinstallingfreshairgrillesinallbedroomsandlivingareasandtoexhaustthe
staleairfromthebathroom,kitchen,andlaundryroom.
A
Independent System
TrueFRESH™ ERV/HRV Ventilation Systems 69-2480EF—05