The following chart lists the thermocouple millivolt readings from 200°F to 600°F.
O V E N T E M P
200°F
250°F
300°F
325°F
350°F
400°F
425°F
450°F
500°F
550°F
600°F
J
90°F 3.26 4.77 6.30 7.06 7.83 9.37
10.14 10.91 12.46 14.00 15.53
U
88°F 3.32 4.83 6.36 7.12 7.89 9.43
10.20 10.97 12.51 14.05 15.59
N
86°F 3.37 4.88 6.41 7.17 7.94 9.49
10.26 11.03 12.57 14.11 15.65
C
84°F 3.43 4.94 6.47 7.23 8.00 9.54
10.31 11.09 12.63 14.19 15.71
T
82°F 3.49 5.00 6.53 7.29 8.06 9.60
10.37 11.14 12.69 14.23 15.76
I
80°F 3.55 5.06 6.59 7.35 8.12 9.66
10.43 11.20 12.74 14.28 15.82
O
78°F 3.60 5.11 6.64 7.40 8.17 9.72
10.49 11.26 12.80 14.34 15.86
N
76°F 3.66 5.17 6.70 7.46 8.23 9.77
10.55 11.32 12.86 14.40 15.94
75°F 3.69 5.20 6.73 7.49 8.26 9.80
10.57 11.35 12.89 14.43 15.97
74°F 3.72 5.23 6.76 7.52 8.29 9.83
10.60 11.37 12.92 14.46 15.99
72°F 3.78 5.29 6.82 7.58 8.35 9.89
10.66 11.43 12.97 14.51 16.05
T
70°F 3.83 5.34 6.87 7.63 8.40 9.95
10.72 11.49 13.03 14.57 16.11
E
68°F 3.89 5.40 6.93 7.69 8.46 10.00 10.78 11.55 13.09 14.63 16.17
M
66°F 3.95 5.46 6.99 7.75 8.52 10.06 10.83 11.61 13.15 14.69 16.23
P
64°F 4.01 5.52 7.05 7.81 8.58 10.12 10.89 11.66 13.20 14.74 16.28
62°F 4.06 5.57 7.10 7.86 8.63 10.18 10.95 11.72 13.26 14.80 16.34
60°F 4.12 5.63 7.16 7.92 8.69 10.24 11.01 11.78 13.32 14.86 16.40
BEARING, CONVEYOR – REPLACEMENT
A. Remove conveyor from oven and place on a flat work surface.
B. Remove connecting links from conveyor belting. See Installation and Operating Instructions
Manual.
C. Remove conveyor belting from conveyor. Remove drive sprocket from drive shaft.
D. Move drive shaft or idle shaft toward end of conveyor, and shaft with bearings will now slip
out of holding bracket.
E. Replace bearing and reassemble in reverse order.