SNUBBER BOARD REMOVAL AND REPLACEMENT (continued)
TROUBLESHOOTING AND REPAIR
F-56 F-56
POWER WAVE 355M/405M
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
PROCEDURE
1. Remove input power to the POWER WAVE
355M/405M.
2. Using a 5/16” nut driver remove the case wrap-
around cover.
3. Perform the Input Filter Capacitor Discharge
Procedure detailed earlier in this section.
4. Locate the snubber board.. See Figure F.23.
5. Remove small lead #B1 from the board. See
Figure F.24.
6. Remove the four bolts using a 7/16” socket. Two
of these bolts have leads #30 and #10 connected
to them. Note the position of all leads and associ-
ated washers upon removal.
7. Carefully remove the snubber board.
8. Replace the snubber board.
9. Replace the bolts, leads, and washers previously
removed. Torque bolt to 30-40 Inch Lbs.
10. Reconnect small lead B1 previously removed.
11. Replace the case wraparound cover.
FIGURE F.23 – SNUBBER BOARD LOCATION
FIGURE F.24 – SNUBBER BOARD LEADS (CLOSE UP)