TROUBLESHOOTING & REPAIR
F-60 F-60
MULTI-WELD 350
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics. OR
• If you repair or replace any electrical components.
IDLE AMPS
Input Volts Maximum Idle Amps
50 – 113 VDC 1 Amp
OPEN CIRCUIT VOLTAGES
Mode Input Voltage Open Circuit Voltage
CC Stick 72 – 113 VDC 74 – 78 VDC
CC Stick 60 – 72 VDC Volts In + 4 VDC
CC Pipe (200 A preset) 72 – 113 VDC 73 – 78 VDC
CV Min. Preset 60 – 113 VDC 17 – 20 VDC
CV Max. Preset 60 – 113 VDC 50 – 54 VDC
LOAD TEST
Mode Input Voltage Output Amps and Volts
CC Stick/Gouge 60 – 113 VDC 100 Amps @ 24 VDC
CC Stick/Gouge 60 – 113 VDC 200 Amps @ 28 VDC
CC Stick/Gouge 60 – 113 VDC 350 Amps @ 34 VDC
FAN AS NEEDED (F.A.N.)
The fan should turn on when the machine is loaded and stay on for 50–70 seconds after the output load is
removed.