A SERVICE OF

logo

- 7 -
MAINTENANCE
WARNING
Always exercise the stopping procedure before
servicing or lubricating the unit.
After servicing the unit, replace and fasten all
guards, shields, and covers to their original
positions before resuming operation.
CAUTION
Always verify fluid levels and check for leaks after
changing fluids.
Do not drain oil onto ground, into open streams,
or down sewage drains.
Maintenance Schedule
1. Check all hardware after the first 5 hours of use, then follow the maintenance schedule.
Fluid Levels
1. MBW #01058---- 6-Pack (8 oz bottles)
MBW #17320---- 1 quart (32 oz)
Engine Maintenance
Refer to the engine owner’s manual for maintenance
intervals and procedures.
Cleaning Plate
Remove any excess debris which may get into the housing
of the unit.
SYSTEM MAINTENANCE
EACH
USE
EVERY 50
HOURS
EVERY 100
HOURS
EVERY 250
HOURS
YEARLY
Engine Refer to engine operator/owner manual X
Clean cooling fins XX
Belts Check for wear and retighten X
Exciter Check oil level X
Check for oil leaks X
Change oil XX
Tighten Bolts
1
XX
Hydraulics Check level and refill X
Hardware
Check and tighten as needed
1
XX
Shockmounts
Check for cracks or tears XX
SYSTEM FLUID VOLUME RECOMMENDED OIL
Exciter
GPR99 32 oz. (0.95 Liter)
MBW Ground Pounder
®
Exciter Oil
1
GPR135 32 oz. (0.95 Liter)
MBW Ground Pounder
®
Exciter Oil
1
Hydraulic Oil
GPR99 8 oz. (.24 Liter) Chevron AW ISO32 or Rykon 32
GRP135 8 oz. (.24 Liter) Chevron AW ISO32 or Rykon 32
Engine Refer to engine operator/owner manual