GENERATOR OUTPUTS
A wide range of voltages are available to supply voltage
for many different applications. Voltages are selected by
applying jumpers (6) to the
(Figure 12). To obtain some of the voltages as listed in
Table 7 (see below) will require a fine adjustment using
the voltage regulator (VR) control knob located on the
control panel.
The (Figure 12) is located on
the control box, behind the generator control panel. This
board has been provided for ease of voltage selection.
Figure 12. Voltage Change-Over Board
attempt to place jumper plates on the voltage
while the generator is in operation.
There exist the possibility of electrocution, electrical
shock or burn, which can cause severe bodily harm
or even death!
3Ø
208V 220V 240V 416V 440V 480V
1Ø 120V 127V 139V 240V 254V 277V
1Ø
120V
Line-Neutral
N/A N/A
240V
Line-Line
N/A N/A
Table 8 shows the maximum amps the generator can
provide. exceed the maximum amps as listed.
DCA300SSC
DCA300SSCU
Single Phase 120 Volt 666.7 amps (4 wire)
Single Phase 240 Volt 333.3 amps (4 wire)
Three Phase 240 Volt 722 amps
Three Phase 480 Volt 361 amps