Mains operation
Rated mains voltage 120–277V, 347–480V,
and 277–480V
Tolerances for safety: +/– 10%
Mains frequency 50/60 Hz
Power factor >= 0.99
DC voltage operation (during emergency back-up)
Because of the run up,T5VHO and HO ExtremeTemperature
lamps (and therefore ballast) are not suitable in combination
with emergency situations.
4.5. Switching cycle effects
The rated average lamp life of T5 lamps is negatively affected
when the switching frequency is higher than the IEC cycle
(3 hrs cycle: 2 hours and 45 minutes on, 15 minutes off).
A = 1.18" (30mm)
B = 1.70" (43.2mm)
C = 16.34" (415mm)
D = 16.70" (424.4mm)
Figure 4.1. T5VHO andT5 HO 4 lamp case dimensions
A = 1.02" (26mm)
B = 1.18" (30mm)
C = 15.65" (397.5mm)
D = 16.34" (415mm)
E = 16.70" (424.2mm)
Figure 4.2. T5 HO 2 lamp case dimensions
OEM Design Guide PhilipsT5VHO and HO ExtremeTemperature Lamps and Ballasts 11