9
5. Display shows Hi P. Device demands more than 750
Watts continuous power.
CycleinverterpowerOFFandON.
If problem persists, use a larger inverter or a
smaller device.
6. Display shows HoT. Inverter is too hot.
Increase ventilation to inverter.
Move inverter to a cooler area.
Reduce the power consumption of the device.
Inverter will automatically reset after cooling.
PROBLEM: Inverter Does Not Turn On
Reason/Solution
1. Poor contact at terminals.
Unplug and reinsert PID-750.
2. Fuse is blown.
A blown fuse is usually caused by reverse polar-
ity or a short circuit within the inverter. To replace,
contactaqualiedservicetechnicianwhowill
diagnose the inverter and replace the fuse with the
appropriate replacement.
3. Inverter may be defective.
See warranty and call Customer Service
800-621-5485(Hours:7a.m.–4:30p.m.CST).