Hydra Pro IV™ Fluid Accessories
840-209 Bleed Line Assembly with Valve
ITEM
NO.
PART
NO.
DESCRIPTION QTY.
1 944-028 Valve, bleed 1
2 103-101 Bleed line assembly 1
3 103-117 Tube
4 538-030 Hose assembly
4
3
2
1
944-028 Bleed Valve Assembly
ITEM
NO.
PART
NO.
DESCRIPTION QTY.
1 944-024 Knob assembly 1
2 944-020 Valve body 1
3 944-004 O-ring 1
4 944-026 Valve stem stop 1
5 761-715 Ball, T.C. 1
6 945-003 Gasket, copper 1
7 944-904 Valve seat 1
103-807 Siphon Valve Assembly
103-808 55 Gallon Siphon Assembly
ITEM
NO.
PART NO. DESCRIPTION QTY.
1 0509762A Rock catcher 1
2 103-575 Tube 1
103-585 Tube (55 gal. siphon ass’y) 1
3 103-679 Hose clamp 2
4 420-070 Hose 5’
5 103-125 Spring 1
6 103-119 Clip 1
7 0509760A Adapter 1
1 2 3 4 5 6 7
1
2
3
4
5
6
7
3
Service Instructions
The 944 Series Relief Valve has a tungsten carbide seat (9) and should not require frequent replacement. The tungsten carbide ball
(7), in normal service, will last a long time because it rotates and wears evenly. If there is leakage, replace the ball.
IMPORTANT: Open the adjustment knob (1) to full counterclockwise position before unthreading valve seat (9) from valve
body (4).
If the valve stem (3) is rotated inwardly with the ball removed, the PTFE O-ring (5) may require replacement. If there has been leakage
from the valve stem, the PTFE O-ring should be replaced.
IMPORTANT: The valve stem stop (6) must be unthreaded from the valve stem (3) with a socket screwdriver, then the valve
stem can be threaded out of the valve body.
IMPORTANT: All non-moving threads must be assembled with Loctite sealant, Titan part # 426-051.