Problem
A. Restricted air ow or no air
ow
B. Filter warning light is on
C. The turbine has no power
D. Excessive arcing/sparking in
the turbine
Cause
1. Air ow adjustment knob on the spray gun
is turned off
2. Air lters are clogged
1. Air lters are clogged
1. No power at the power supply
2. The fuse is blown
3. Worn turbine brushes
1. Worn turbine brushes
2. Damaged commutator
Solution
1. Adjust the air ow adjustment knob
2. Clean or replace the lters
1. Clean or replace the lters
1. Check the power supply
2. Check and replace the fuse
3. Have the brushes replaced at an authorized Titan
service center
1. Have the brushes replaced at an authorized Titan
service center
2. Replace the turbine (contact a Titan service
technician)