Xact Digital Control System Error Messages
The following error message screens appear whenever the Xact
Digital Control System detects a problem with the sprayer. Once
a problem occurs and the error message appears, the sprayer
will shut down.
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer
before servicing!
Check Paint Screen (E1)
CHECK PAINT
The Check Paint screen appears when
the pump pressure drops to a very
low level and the pressure control knob has not been adjusted.
Check the paint level and rell. Restart the sprayer by following
the “Painting” procedure in the Operation section of this manual.
Check Transducer Screen (E2)
CHECK TRANSDUCER
The Check Transducer screen appears
when the transducer has become
disconnected or is defective. Take the sprayer to a Titan
authorized service center for repair.
Check Motor Screen (E3)
CHECK MOTOR
The Check Motor screen appears when
the motor or motor sensor is defective.
Take the sprayer to a Titan authorized service center for repair.
Low Voltage Screen (E4)
LOW VOLTAGE
The Low Voltage screen appears when
the sprayer shuts down because of low
input voltage. Check the power supply and correct the problem.
Restart the sprayer by following the “Painting” procedure in the
Operation section of this manual.
High Motor Temperature Screen (E5)
HIGH MOTOR
TEMPERATURE
The High Motor Temperature screen
appears when the temperature of the
motor has risen too high. Take the sprayer to a Titan authorized
service center for repair.
High Control Temperature Screen (E6)
HIGH CONTROL
TEMPERATURE
The High Control Temperature screen
appears when the temperature of the
Xact Digital Control System has risen too high. Take the sprayer
to a Titan authorized service center for repair.
High Load Check Mechanism Screen (E7)
HIGH LOAD
CHECK MECHANISM
The High Load Check Mechanism
screen appears when the sprayer shuts
down because of high current or when the sprayer goes into
current fold back mode.. Take the sprayer to a Titan authorized
service center for repair.
Exceeded Pressure Limit Screen (E8)
EXCEEDED
PRESSURE LIMIT
The Exceeded Pressure Limit screen
appears when the sprayer pressure
exceeds 3300 PSI / 22.8 MPa. Take the sprayer to a Titan
authorized service center for repair.
Communication Error Screen (E9)
COMMUNICATION
ERROR
The Communication Error screen
appears when the Xact Digital Control
System loses communication with the control panel. Take the
sprayer to a Titan authorized service center for repair.