A SERVICE OF

logo

© Titan Tool Inc. All rights reserved. 7
Unit Serial # Screen
UNIT SERIAL #
SELECT-4 MENU-1
The Unit Serial # screen shows the
sprayers serial number.
SER # XXXXXXXXXX
PRESS 1 FOR MENU
To select the Unit Serial # screen, press
the #4 key.
Timers Screen
TIMERS
SELECT-4 MENU-1
The Timers screen shows the total time
the sprayer has been turned on as well
as the total time the sprayer has been running (pumping).
ON TIME XXXXX:XX
RUN TIME XXXX:XX
To select the Timers screen, press the
#4 key.
Job Timers Screen
JOB TIMERS
SELECT-4 MENU-1
The Job Timers screen allows the user
to reset the “ON TIME” and “RUN TIME”
to track time on specic jobs.
ON TIME XXXXX:XX
RUN TIME XXXX:XX
To select the Job TImers screen, press
the #4 key. The screen will toggle
between the timers and a screen that allows the user to reset the
timers.
Service Time Screen
SERVICE TIME
SELECT-4 MENU-1
The Job Volume screen allows the user
to reset a gallon counter to track usage
on specic jobs.
The Service Time screen allows the user to set a service time
interval (in hours). Below the set time, the screens shows the
current amount of hours on the sprayer. To select the Service
Timer screen, press the #4 key.
SERVICE @ XXXHR
RUN HOURS XX
The screen will toggle between the
service hours and a screen that allows
the user to change the service time interval.
When the service time interval is set and met by the run hours,
the display will toggle between the “Main screen” and a “Service
Required” screen at sprayer startup. To stop the toggling, scroll
to the “Service Time” screen and either set a new service time
interval or set the service time to “0”.
Pressure Screen
PRESSURE
SELECT-4 MENU-1
The Pressure screen allows the user to
see the current set point pressure as
well as the actual working pressure.
SET PSI 3000
ACTUAL PSI 2950
To select the Pressure screen, press
the #4 key. This screen is also the Main
Screen.
Security Code Screen
SECURITY CODE
SELECT-4 MENU-1
The Security Code screen allows the
user to set a four digit security code
to prevent unauthorized use of the sprayer. If a security code
has been set, the control system display will ask for the code at
startup. If the correct code is entered, the display will show the
Main Screen and the sprayer will operate. If the wrong code is
entered, the display will continue to ask for the correct code and
the sprayer will be disabled. To set or change the security code,
press the #2 key.
NOTE: If the sprayer is new, no security code is set and
the Main Screen will appear at startup. Also,
whensettingasecuritycodeforthersttime,the
“Enter Old Code Number” screen will not appear.
ENTER OLD CODE
NUMBER
Enter the old security code number to
access the screen that allows the code
change. If the wrong code is entered, the display will continue to
ask for the correct code and the security code cannot be changed.
ENTER NEW CODE
NUMBER
Enter the new security code. Once the
new code is entered, the display will
automatically ask that the new code be re-entered for verication.
If the same new code is re-entered, the display will conrm that
the new code has been accepted and return to the Main Screen.
If the new code is re-entered incorrectly, the display will return to
the “Enter New Code Number” screen and the process will repeat.
NOTE: To inactivate the X-Lock security function, enter
“1111” at the “Enter New Code Number” screen
(this is the default code that leaves the sprayer
unlocked). As a result, the Main Screen will
appear at sprayer startup.
Prime Screen
PRIME
The Prime screen appears when the
pressure control knob is set at the “Min”
setting in the yellow zone.
Pulse Clean Screen
PULSE CLEAN
ACTUAL PSI XXXX
The Pulse Clean screen appears when
the pressure control knob is set at the
PULSE CLEAN position in the red zone and the PRIME/SPRAY
valve is in the PRIME position.
NOTE: If there is no action at any menu screen for 30
seconds, the display will go back to the Main
Screen.
Pressure Relief Procedure
Be sure to follow the pressure relief procedure
when shutting the unit down for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray tips, or
preparing for cleanup.
Trigger lock in
locked position.
1. Lock the gun by turning the gun trigger
lock to the locked position.
2. Turn off the sprayer by moving the ON/
OFF switch to the OFF position.
3. Turn the pressure control knob
counterclockwise to its OFF position in
the black zone.
4. Unlock the gun by turning the gun
trigger lock to the unlocked position.
5. Hold the metal part of the gun rmly to
the side of a metal container to ground
the gun and avoid a build up of static
electricity.
6. Trigger the gun to remove any
pressure that may still be in the hose.
7. Lock the gun by turning the gun trigger lock
to the locked position.
8. Move the PRIME/SPRAY valve down to the
PRIME position.