18 19
Reattach door to range.
Open door completely. Reattach hinge trim.
Remove pins from hole in hinges.
Close door.
If the door needs to be adjusted, loosen hinge trim screws located in
step 2. Adjust the screws located between the door and kickplate using a
5/32” hex head allen wrench. After adjustment, tighten hinge trim screws.
Door Replacement and Adjustment
Install backguard.
Burner caps are packed in styrofoam top pack with the grates.
Place burner on top of range. Place burner grate on top of burner
cap and grate support.
Note: Arrow on burner cap must be pointing towards back of range.
4
3/8”
3/8”
(
0
.
9
5
cm
)
(0.95 cm)
3/8”
(
0
.
9
5
cm
)
Check that unit is level side to side
and front to back. The side trim must be 3/8” (0.95 cm)
above countertop. If unit is not level repeat steps 5-7
of “Leveling/Adjustments/Alignment” section.
Slide range into place. Be sure
anit-tip bracket slides into the anit-tip opening.
Final Installation
Unscrew four standoff brackets and remove.
Standoff Bracket Removal (VGSC Self-Clean Models Only)
Note: Standoff brackets can only be removed if range is installed against a NON-COMBUSTIBLE wall.
FIRE HAZARD
Standoff brackets provide a
3/8” barrier between back of
range and rear wall. These
must be in place for adequete ventilation.
The standoff brackets may only be
removed if range is installed against a
non-combustible wall.