5
The configuration menu allows you to set certain thermostat
operating characteristics to your system or personal
requirements.Toenterthemenu:SetyourthermostattoOFF
and press the and buttons simultaneously. The display
willshowtherstiteminthecongurationmenu.PressRUN/
Configuration Menu
Menu
Reference
Number
Press
Key
Displayed
(Factory
Default)
Press
or
to select from
listed options
Comments
1
and
SS HP SelectSingleStage(SS)or
HeatPump(HP,1compressor)
2 RUN/HOLD* CS
(OFF)
On SelectCoolSavingsFeatureOnorOFF
RUN/HOLD* CS
(3)
1,2,3,4,5,6 IfCSselectedOn,selectsCoolSavingsvalue
3 RUN/HOLD* E
(On)
OFF SelectEnergyManagementRecoveryOnorOFF
4 RUN/HOLD* CRHeat
(ME)
FA,SL SelectAdjustableAnticipation,cyclerate,
HeatSingleStage
5 RUN/HOLD* CR Cool
(FA)
SL SelectAdjustableAnticipation,cyclerate,
CoolSingleStage
6 RUN/HOLD* CL
(OFF)
On SelectCompressorlockoutOFForOn
7 RUN/HOLD* L
(On)
OFF SelectDisplayLightOnorOFF
8 RUN/HOLD* Temp
(0HI)
4 LO to
4HI
Selecttemperaturedisplayadjustmenthigherorlower
9 RUN/HOLD*
o
F
o
C Select
o
F/
o
CDisplay(temperatureunitsinFahrenheit
orCelsius)
10 RUN/HOLD* Change Filter
(OFF)
On SelectlterreplacementindicatorOFForOn
RUN/HOLD* Change Filter
(200h)
25to1975 If Change Filter selected On, selects time interval for
ChangeFilterIndicator.(in25hourincrements)
11 RUN/HOLD* Returns to normal operation
*PressRUN/HOLD to advance to next item or TIME to move backwards to previous item
INSTALLER/CONFIGURATION MENU
1) System Configuration-SelectsSS(SingleStage)orHP
(HeatPump)operatingmode.DefaultcongurationisSS.
ForHeatPumpoperationchooseHP.
2) Select CS (Cool Savings™) - With Cool Savings™
enabled, thethermostat will make small adjustments to
theSetpointtemperatureduringperiodsofhighdemand
to reduce cooling system running time and save energy.
Whenthecoolingsystemhasbeenrunningformorethan
20minutes,humidityinthehomewillbelowerandahigher
setpointtemperaturewillfeelcomfortable.After20minutes
of run time, the thermostat will start increasing the setpoint
temperature in steps of less than one degree as the system
continuestorun.Theseadjustmentswilleventuallycause
the system to satisfy the thermostat and turn the system off
toreducetheenergyconsumption.WhentheCoolSavings
featureisactiveandmakingadjustments,thedisplaywill
show“Save”.Theamountoftheadjustmentstothesetpoint
temperatureisdependentontheCoolSavingsvaluethat
isset,1beingtheleastadjustmentand6beingthemost
adjustment.WiththisfeaturesettoOFF,no changewill
occur when the cooling system is continuously running
during the periods of high demand. Periods of high demand
will normally occur during the late afternoon and early
evening on the hottest days of the summer.
3) Select Energy Management Recovery - Energy
Management Recovery (E) On enables the thermostat
to start heating or cooling early to make the building
temperature reach the program setpoint at the time you
specify.Heatingwillstart5minutesearlyforevery1°of
temperature required to reach setpoint.
4 & 5) Select Cycle Rate Selection - The factory default
settingforSingleStageHeatisMediumCycle(ME).For
SingleStageCoolthedefaultsettingisfast(FA).Tochange
cycle rate, press the
and buttons.
The cycle rate differentials for different settings are:
MODE Fast Medium Slow
(FA) (ME) (SL)
SSHeat 0.6°F 0.8°F 1.2°F
SSCool 1.2°F - 1.7°F
6) Select Compressor Lockout CL OFF or ON-Selecting
CLOnwillcausethethermostattowait5minutesbetween
cooling cycles. This is intended to help protect the
compressorfromshortcycling.Somenewercompressors
already have a time delay built in and do not require this
feature.Yourcompressormanufacturercantellyouifthe
HOLDtochangetothenextmenuitemorpressTIMEtogo
backwards to the previous item in the menu. To exit the menu
andreturntotheprogramoperation,pressPRGM.Ifnokeys
are pressed within fifteen minutes, the thermostat will revert to
normal operation.