6
Dimensions in parentheses are in
millimeters unless otherwise specified.
Planning Information
Pro 24" (610) Deep Wall Ventilation Hood
MODEL PW302418(R)
Ducting for Pro 24" (610)
deep wall hoods.
DUCTING CONSIDERATIONS
Wolf Pro 24" (610) deep wall hoods are shipped
without the blower assembly. Internal, in-line
and remote blower assemblies are available.
IMPORTANT NOTE: Install this ventilation hood
only with a Wolf blower.
Pro 24" (610) deep wall hoods have a vertical
discharge. A horizontal discharge kit is available
as a sales accessory.
The hood will operate most efficiently when
ductwork does not exceed 50' (15 m) in length.
Local building codes may require the use of
make-up air. Consult your local HVAC professional
for specific requirements in your area.
IMPORTANT NOTE: Wolf Pro 24" (610) deep wall
hoods must be vented to the outside except when
used with the accessory recirculating kit with the
600 CFM blower. Use only metal ductwork.
Refer to the illustration below for ducting
considerations for Pro 24" (610) deep wall hoods.