POWER SUPPLY PANEL
REMOTE IN
Terminal to connect Remote cable, which comes from the
source and which controls the amplifier switching on. Applied
voltage must be between 7 and 15VDC.
1
REMOTE OUT
Terminal to repeat the switching on control (Remote IN) coming from the source. It is used to
switch on another amplifier or device in the system simultaneously. Available voltage is the same
as the one applied on Remote IN.
2
VCR (optional kit)
Terminals to connect VCR01/VCRA/VCRD adjuster included in sub output volume remote control
kits (VCR01K/VCRAK/VCRDK).
3
FUSE (50A)
Strip fuse. It insures the amplifier general protection. In case the fuse breaks down, please replace
it by respecting its original value.
CAUTION: If you want to protect the system even more, please put a strip fuse onto the cable
which connects the battery positive pole to the amplifier POWER (+) terminal block (see “Electric
connections”).
4
POWER
Terminal blocks for the amplifier power supply cable connection. Connect positive and
negative poles according to indicated polarities. Holes have 8mm diameter and accept cables
up to 3 A.W.G. max. In order to get the best current transfer, please use power supply cables
with as big a section as possible. audison cable catalogue offers you a complete range of such
products which can satisfy whatever demands; you can also find Maincrimp terminals in it. We
strongly recommend their use because they contain the cable non protected end and allow the
terminal block to fasten all its useful section.
5
IN OUT
REMOTE
FUSE
POWER
1
2
3
4
5
FUNCTIONS
19
CONFIGURATION EXAMPLES
Front Rear
+
+
LRx 2
Config. 3
Rear
Tweeter
Woofer
Tweeter
Woofer
Subwoofer
LRx 5.600
Config. 3
Tweeter
Woofer
Front L
Front R
+
+
Tweeter
Woofer
+
Pre Out
3 CHANNEL FRONT+REAR