Rear Panel Features
1. MAIN INPUT
This is a female XLR-type connector that accepts
a balanced line-level signal from a mixing console or
othersignalsource.SeeAppendixBformore
information about this connector.
2. LOOP OUT
This is a male XLR-type connector that produces
exactly the same signal that is connected to the main
inputjack.Useittodaisy-chainseveralHD1221's
togetheroffthesamesignalsource.SeeAppendixBfor
more information about this connector.
3. VOICING MODE
Thisbuilt-in3-positionvoicingmodeswitchallowsthe
HD1221 to be tailored for any sound application.
CONTOUR
SettheVoicingModeswitchtothe‘CONTOUR’
position for low-level applications. This is the
perfect setting when a little more low and high
end is necessary. The LED next to the switch
willilluminateyellowwhen‘CONTOUR’isthe
chosen voicing mode.
NORMAL
This is the standard position of the switch,
hencethename,‘NORMAL’.Itisidealformost
PA applications where the HD1221 will be
cranked. Additionally, this is the recommended
positionwhenpairedwithasubwoofer.Ofthe
three options, this is the most accurate voicing
mode and should be used in the majority of
applications. The LED next to the switch will
illuminategreenwhen‘NORMAL’isthechosen
voicing mode.
MONITOR
The‘MONITOR’positionisdesignedforwhen
the HD1221 will be used as a stage monitor,
butitmayalsobeutilizedwhenyouneedthe
vocals to cut through a high-gain, high-output
instrument(suchasguitar).Inthisposition,
the low frequency is rolled off, while the
mids and highs are tuned to cut through stage
volume with as much gain before feedback
as possible. The LED next to the switch will
illuminateredwhen‘MONITOR’isthechosen
voicing mode.
POWER
LIGHT ON
SIG/ LIMIT
THERMAL
MAIN
INPUT
LOOP
OUT
LEVEL
+6dB 6dB
-
HD1221
2-WA Y HIGH DEFINITION POWERED LOUDSPEAKER
VOICING MODE
NORMAL
CONTOUR
MONITOR
POWER
ON
RE VISIO N
SE RIAL NUMB ER
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR
MOISTURE. DO NOT REMOVE COVER. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
AVIS:
RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR
PARALLEL
7
Owner’s Manual
Owner’s Manual
1 2 3 4
8
9
5
6
7