Sanyo XH4242 / CH4242 Car Speaker User Manual


 
I - 84
SM830082
1
2
3
4
5
1. Specifications
1-9 Performance Charts
Cooling Characteristics
(2) Operating Pressure
11
11
1 Indoor Unit: 24 Type Outdoor Unit: CH2442
High Pressure
High pressure characteristics versus outdoor ambient temperature and indoor temperature.
(Indoor relative humidity: 50%, Indoor fan speed: High)
230V / 208V
Outdoor fan speed
Low
High
1161_X_S
85 (30)
80 (27)
75 (24)
70 (21)
Discharge pressure (psig)
300
320
340
220
200
240
260
280
180
160
59 68 77 86 95 104
(15) (20) (25) (30) (35) (40)
Outdoor ambient temp. °F (°C)
Indoor
temp.
°F (°C)
Low Pressure
Low pressure characteristics versus outdoor ambient temperature and indoor temperature.
(Indoor relative humidity: 50%, Indoor fan speed: High)
230V / 208V
1162_X_S
Indoor
temp.
°F (°C)
Suction pressure (psig)
70
60
80
90
100
50
40
59 68 77 86 95 104
(15) (20) (25) (30) (35) (40)
Outdoor ambient temp. °F (°C)
85 (30)
80 (27)
75 (24)
70 (21)
Outdoor fan speed
Low