NSR-1000 Series v1.1.1 Release Note
4 Limitations
4-1 Known Limitations
4-1-1 Installation / System Configuration
・ When
enabling the SNMP agent function under [Administration] menu ->
[Setup] menu -> [SNMP Menu] ->[Trap], the error message below is displayed
and the ERROR lamp is lit.
There is no problem in operation, however, because it is displayed when
service automatically restarts itself. (V11N:165)
wixalarm[1234] is dead or killed
4-1-2 Device Registration
・ Devices
which have already been registered may be displayed on ‘Unregistered
Cameras’ list in ‘Open the Multiple Camera Registration Window’. In this case,
please update the list with ‘Reload’ button. (VT1:764)
・
4-1-3 Main Window - Search and Play back
・ A
udio cannot be output when playing audio in files which is currently recorded
from search result. (VT1:1668)
・ If user tries to start playback with selecting alarm history after change layout
from the one to 1x1 with double-clicking the monitor frame, the layout is back
to former layout. Please start playback with selecting alarm history except 1x1
layout and double-click the monitor frame to display 1x1. (VT1:1689)
・ During quick playback, when clicking [Go] button after specifying nonexistent
date and time on the main screen, a message “No Record” appears and the
mode is restored from [PLAYBACK] to [LIVE].(V11N:20)
・ [S/C] When playing back the images just before recorded while recording,
playback may pause within a few minutes. To resume playback, press the PLAY
button. (V11N:25)
・ If you specify “iSCSI” as recording storage, and specify “00:00:00 to 24:00:00”
- 19 -