SV Sound PB12-Plus Car Speaker User Manual


 
© 2011 Specialty Technologies, LLC
Call SVSound
877.626.5623
www.svsound.com
SVSound
STA-800D/1000D Equipped Subs
Refertothesectionlaterinthisguidetitled“AdvancedFeatures:ParametricEqualizer(PEQ)”formoredetails
onhowtoactuallyusethePEQfeaturesoftheSTA-800D/STA-1000D.
From the IFC WELCOME screen, single-click the IFC knob and rotate the IFC knob seven clicks clockwise until
thedisplayreads“MENU/P-EQ”.Single-clicktheIFCknobtoselectthePEQ1FunctionorrotatetheIFCknob
clockwiseorcounter-clockwiseandsingle-clicktoselectPEQ2Function.
FromthePEQ1/PEQ2Functionmenu,single-clicktoselectthedesiredPEQbandFrequencymenu(toskipto
theLevelMenuorQMenu,turntheIFCknobtheappropriatenumberofturns).Single-clicktochangethePEQ
band center frequency. When selected, the display will be blinking and the value will change as the IFC knob is
turned.Availablecenterfrequenciesinclude31,35,40,46,50,56,63,70,80,90,100,112,or125Hz.Tosave
thedisplayedfrequency,single-clicktheIFCknob.ToproceedtoeithertheLevelMenuorQMenurotatethe
IFC the required number of turns.
ToadjusttheLevel,single-clicktheIFCknobwhenthedisplayreadsPEQ1orPEQ2LEVEL.Thescreenwillbeginto
ashandyoucanchangetheLevelofthePEQlterbyturningtheIFCknobclockwiseorcounter-clockwise.(NOTE:
TodisablethePEQ1orPEQ2lter,setthelevelto0dB.)TheLevelcanbeadjustedfrom+3to-12dBin1dBincre-
ments.Tosavethedisplayedlevel,single-clicktheIFCknob.ToproceedtotheQMenu,rotatetheIFCknob.
Note: Some dips are actually nulls and boosting a null will not produce an increase in level when a positive
valueisapplied.Tolimitpotentialdamagetothesubwoofer,theamountofboosthasbeenlimitedto+3dB.
ToadjustQ(width)forthePEQ1orPEQ2lter,single-clicktheIFCknobwhenthedisplayreadsPEQ1orPEQ2
Q.ThescreenwillbegintoashandyoucanchangetheQofthePEQlterbyturningtheIFCknobclockwise
orcounter-clockwise.Qvaluescanbesetto2.0,2.4,2.9,3.6,4.8,5.7,7.2,9.6,or14.4.Tosavethedisplayed
Qvalue,single-clicktheIFCknob.
Atthispoint,asingle-clickwillreturntoeitherthePEQ1orPEQ2FunctionMenuunlesstheLevelissetto0dB.
Ifthatisthecase,asingle-clickwillreturntothePEQMenuwherethePEQ1orPEQ2functioncanbeselected.
To return to the top-level menu, double-click the IFC knob.
Integrated Function Controller
18