Toro RDR0160LVCE Car Satellite TV System User Manual


 
Table 2 - Hand-Held Radio Command Codes (continued from p. 5)
Code Operation Description
7512 Syringes individual stations for a predetermined time. Use command 8006 01 to set the syringe time; e.g. 7512 01 02
turns on stations 1 and 2 for the specified time.
7513 Disables individual stations; e.g., 7513 01 03 disables stations 1 and 3. After this command, on and off commands will
be ignored for stations 1 and 3 until the stations are re-enabled. (See 7514.)
7514 Enables individual stations; e.g., 7514 01 03 enable stations 1 and 3.
7515 Sequentially syringes a specified station number range; e.g., 7515 05 11 will syringe stations
5 through 11 sequentially. Command 8006 01 sets the syringe time.
7516 Sequentially syringes individual stations; e.g., 7516 10 11 will syringe stations 10 and 11.
Note: Multiple syringe groups can also be run. Enter two stars between stations to designate separate syringe groups;
e.g., 7516 10 11
**
22 24 26 28 will run two syringes at the same time. First on stations 10 and 11, followed by stations
22, 24, 26 and 28.
7517 Turns on individuals stations for a specified number of hours, minutes and seconds;
e.g., 7517 01 30 00 05 06 09 turns stations 5, 6 and 9 on for 1 hour, 30 minutes and no seconds.
7518 Turns on individual stations for a specified number of minutes; e.g., 7518 10 05 06 turns on stations 5 and 6 for 10
minutes.
7520 Turns off a sequential station run operation (initiated by command code 7521).
7521 Turns on a sequential station run operation; e.g., 7521 01 turns on station 1. To step forward through the stations,
press
*
1; to step back through the stations, press
*
2.
7522
Increment to the next predetermined station in a sequential run; e.g., 7522 02 will add 02 to the station number of the
currently running station and energize the new station number. The sequential run will stop when the new number exceeds 64.
7523
Decrement to the previous predetermined station in a sequential run; e.g., 7523 03 will run the station that is 3 stations
before the one currently running. The sequential run will stop when station number reaches the new station number minus 1.
7524 Turns on individual stations as switches; i.e., does not simultaneously energize the pump. Note: Will not turn off the
pump if already running. E.g., 7524 01 03 11 turns on stations 1, 3 and 11 without energizing the pump.
7525 Turns on individual stations as switches for a time given in minutes; i.e., does not simultaneously energize the pump
in this command string, the run time is entered first, followed by the station numbers; e.g., 7525 25 05 11 turns on stations
5 and 11 for 25 minutes without energizing the pump.
7526 Turns on individual stations as switches for the time given in hours, minutes and seconds.
In this command string, the run time is entered first, followed by the station numbers; e.g., 7526 02 30 45 05 06 07 turns
on stations 5, 6 and 7 for 2 hours, 30 minutes and 45 seconds.
7540 Turns off all stations (this satellite only).
7542 Turns off all stations using the sequential shut down feature.
7543 Disables all stations in all satellites (rain shutdown). Note: Satellite address code 256 is used with 7543 or 7544
command codes. The stations will not respond to any further commands until enabled.
7544 Enables operation of all stations in all satellites. See Note above.
7546 Sequentially syringes all stations for a set length of time; e.g., 7546 turns on all stations for the predetermined number
of 30 second intervals as defined in the syringe time.
7800 Disable the remote relay on the frequency decoder module.
7801 Enable the remote relay on the frequency decoder module.
7810 Turns off the remote relay on the decoder module.
Resumes function to the satellite unit.
7811 Turns on the remote relay on the decoder module. Disables function to the satellite unit.
8000 Disables pump start.
8001 Enables pump start to be assigned to a station
; e.g., 8001 10 assigns pump start to station 10.
8003 00 Disables operation and turns off all stations in the satellite with sequential shutdown.
8003 01 Enables operation of all stations in the satellite.
8004 Changes the password
; e.g., 8004 7531 6108 will change the factory default password (7531) to 6108.
8006 01 Sets the syringe time in 30-second intervals; e.g., 8006 01 0100 (without a password) or 8006 pppp 01 0100.(with a
password) sets the syringe time to 100 intervals (50 minutes). The number of intervals must be given as four digits with
leading zeros but can be no greater than 0255.
8006 02 Sets the time-out limit in 30-minute intervals. Must be specified using four digits with leading zeros and no greater value
than 0255; e.g., 8006 02 0060 (without password) or 8006 pppp 02 0060 (with password) sets the time-out limit to 30 hours.
8006 03 Enables/disables the password. Use 8007 03 01 to enable password protection or 8007 03 00 to cancel password protection.
8007 03 00 Password disable command. Cancel the requirement of entering the password for every entered command.
8007 03 01 Password enable command. After activation, all commands will require the password to be entered.
8008 Configures stations as switches. Stations can be specified individually and in combination with a range of stations;
by using the star key; e.g., 8008 01 03 08
*
11 configures stations 1, 3 and 8 through 11 as switches.
8009 Configures stations for irrigation. Stations can be specified individually and in combination with a range of stations;
by using the star key; e.g., 8008 01 03 08
*
11 configures stations 1, 3 and 8 through 11 for irrigation.
8011 Resets EPROM to factory defaults.
*
1 Sends command 752201 to the last satellite addressed. Increments station number in test mode by one.
*
2 Sends command 752301 to the last satellite addressed. Turns off current station be tested and decrements station
number in test mode by one.
*
4 Sends command 7540 to the last satellite addressed. Turns off all stations
6