Diagnostic Messages
57
Temperature unknown.
After the pump has been running for 2 minutes, the
temperature will be displayed
“Overheat” - The spa has shut down. One of the
sensors has detected 118°F/48°C at the heater.
DO NOT ENTER THE WATER. Remove the spa cover
and allow water to cool. Once the heater has cooled,
reset by pushing any button. If spa does not reset, shut
off the power to the spa and call your dealer or service
organization.
“Overheat” - The spa has shut down. One of the
sensors has detected that the spa water is 110°F/43°C.
DO NOT ENTER THE WATER. Remove the spa
cover and allow water to cool. At 107°F/42°C, the spa
should automatically reset. If spa does not reset, shut
off the power to the spa and call your dealer or service
organization
“Ice” - Potential freeze condition
No action required. The pump and blower will automatically
activate regardless of spa status.
Spa is shut down. The sensor that is plugged into the
Sensor “A” jack is not working.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)
Spa is shut down. The sensor that is plugged into the
Sensor “B” jack is not working.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)