![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/dd/1dd57a7d-ea87-3024-510d-76ce3f70e664/1dd57a7d-ea87-3024-510d-76ce3f70e664-bg10.png)
16
108382
UNVENTED GAS LOG HEATER
FLAME-MAX
®
For more information, visit www.desatech.com
OPERATING
HEATER
Continued
Figure 26 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA only)
Figure 25 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for
Remote Operation
Selector Switch in Remote Position
(Optional Remote Control)
ON
OFF
REMOTE
O
F
F
P
I
L
O
T
O
N
L
O
I
H
Control Knob in
On Position
Flame Adjustment Knob
Figure 27 - Correct Pilot Flame Pattern
(Propane/LP Pilot Shown)
Pilot Burner
Thermocouple
Figure 28 - Incorrect Pilot Flame Pattern
(Propane/LP Pilot Shown)
Check pilot flame pattern and burner flame
patterns often.
PILOT FLAME PATTERN
Figure 27 shows a correct pilot flame pattern.
Figure 28 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touch-
ing the thermocouple. When the thermo-
couple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 28
• turn heater off (see To Turn Off Gas to
Appliance, page 15)
• see Troubleshooting, pages 18 through 20
Pilot Burner
INSPECTING
BURNERS
Thermocouple
IMPORTANT:
This remote control
has been specially engineered to
take an air temperature sample ev-
ery 5.5 minutes in the AUTO mode.
It will not respond immediately to
the temperature setting being
turned up or down.
IMPORTANT:
The hand-held re-
mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close to the
heater. The thermostat on the hand-
held remote control unit will heat up
too quickly and turn the heater off.
3. To turn the burner off, press the
AUTO/ON/OFF button until OFF
lights. The pilot will remain lit.
IMPORTANT:
To turn the pilot off,
manually turn the control knob on the
heater to the OFF position.
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burners
On or Off and
Allows You to
Choose the Auto
Setting
Shows Temperature Setting
The Log Heater will
Automatically Cycle
between Pilot and the
Heat Setting that has
been Selected