![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/10/610e52bb-d6be-44ce-bc93-ed6070f50d11/610e52bb-d6be-44ce-bc93-ed6070f50d11-bg9.png)
A-1
INSTALLATION
A-1
RATED OUTPUT
OUTPUT
RECOMMEND INPUT WIRE AND FUSE SIZES
REQUIRED GAS FLOW RATE REQUIRED GAS INLET PRESSURE
TECHNICAL SPECIFICATIONS - PRO-CUT 55
Duty Cycle
50% Duty Cycle
100% Duty Cycle
Current
Range
25-60 Amps
Open Circuit
Voltage
MAX
335 VDC
For all plasma cutting applications Based on U.S. National Electrical Code
Ambient Temperature 30
o
C or Less
Pilot Current
18 Amps @ 100% Duty Cycle
AMPS
55
40
VOLTS
108
100
70 PSI @ 360 SCFH
( 4.8 Bar. @ 10160 LHR)
80 to 150 PSI
( 5.4 Bar. TO 10.2 Bar.)
THREE PHASE SINGLE PHASE
Standard Input Current
Voltage at Rated Output Model
208/230/460 31/28/17 50/60 Hz
200/380-415 30/17/16 50/60 Hz
460/575 17/14 50/60 Hz
Standard Input Current
Voltage at Rated Output Model
208/230/460 60/55/30 50/60Hz
INPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Type 75°C
Type 75°C Copper
Fuse Copper Ground
(Superlag) Wire in Wire in
Input or Conduit Conduit
Voltage Breaker AWG (IEC) AWG (IEC)
Frequency
(1)
Size Sizes Sizes
208/50/60 40 10 (6mm
2
) 10 (6mm
2
)
230/50/60 40 10(6mm
2
) 10 (6mm
2
)
460/50/60 30 10 (6mm
2
) 10 (6mm
2
)
200/50/60 40 10 (6mm
2
) 10 (6mm
2
)
380-415/50/60 30 10 (6mm
2
) 10 (6mm
2
)
460/50/60 30 10 (6mm
2
) 10 (6mm
2
)
575/50/60 30 10 (6mm
2
) 10 (6mm
2
)
Type 75°C
Type 75°C Copper
Fuse Copper Ground
(Superlag) Wire in Wire in
Input or Conduit Conduit
Voltage Breaker AWG (IEC) AWG (IEC)
Frequency
(1)
Size Sizes Sizes
208/50/60 80 8 (8.4mm
2
) 8 (8.4mm
2
)
230/50/60 80 8 (8.4mm
2
) 8 (8.4mm
2
)
460/50/60 40 10 (6mm
2
) 8 (8.4mm
2
)
THREE PHASE SINGLE PHASE
Weight
Including Machine, Torch and
Torch Cable (Length)
(25ft/7.6m) (50ft/15.2m)
70 lbs. 85 lbs.
32 kg. 39 kg.
PHYSICAL DIMENSIONS
Depth
26.0 in.
660 mm
W
idth
11.0 in.
280 mm
Height
12.6 in.
320 mm
(1) Input voltage must be within ±10% of rated value.