1/1
Service Technical Information
MODEL NO. SUFFIX
TV C2121 / A21T1 / A2126 KERJ2C,KEJ2C−
/ SHJ2C / SHJ2C
SUBJECT
NO POWER REF No :G A 2 02 8 E 0−− −
DATE :05.SEP.2002
<SYMPTOM>
There may be a case of not turning on the power reason of DY coil defective.
<REPAIR>
1. Replace CRT Ass’y and Q601.
2. Making necessary adjustments (ex. White Balance, etc.) after replacing CRT.
(Refer to the service manual)
Note. The below mentioned CRTs are pre adjusted PURITY and CONVERGENCE.−
<CAUTION>
Must discharge residual anode voltage before replacing CRT. If failed to do, there is a possibility
to cause electric shock hazard. Refer to the service manual for discharging.
Ref. Parts Code Description Remarks
V901 8Z JB9 611 010 CRT,A51QAE320X45CQMA TV C2121(KERJ2C)−−− −
V901 8B JAN 650 010 CRT,A51QAE320X45CMMA(0,35) TV A21T1, TV A2126,−−− − −
TV C2121(KEJ2C)−
−−− − −Q601 87 A30 633 010 TR,2SD2627LS YB
G R Code No. Access Code Modified Ser. No. Parts Schedule
−− − − − −