Notes on repairing REF.No. :G 99 076 E1−− −
DATE :18. FEB. 2002
REVISION : Amended the SUBJECT and the <CONTENTS>.
<CONTENTS>
Pay attention to the following notes when repairing the TV F2400/F2000.−
Do not leave the degaussing cable disconnected when repair a unit.
Conventional TV sets allow repairing work with a degaussing cable removed.
Turning on the power of a TV F2400 / F2000 with neither degaussing coil results in breaking a−
cement resistor which is inserted in parallel to the degaussing coil.
Be sure to connect a dummy load when removing a degaussing coil.
Scheme 1 :Use another degaussing coil to be connected for repairing.
Scheme 2 :Use a 6.8Ω 20W resistor, as the jig to be connected to the connector of−
degaussing coil.
Turning on the power of a unit with neither degaussing coil or dummy load results in
opening a fixed resistor which is inserted in parallel to the degaussing coil.
The following shows relations between the models concerned and the cement resistors.−
Model Ref No. Value Parts Code Affected Serial No.
TV F21ST1 R848 56W/2W 87 A00 659 010 S 9C ~− − − − ∗∗∗∗ ∗∗∗∗∗
TV F25ST1 R848 27W/2W 87 A00 655 010 S 9C ~− − − − ∗∗∗∗ ∗∗∗∗∗
TV F2400 R801 27W/2W 87 A00 661 010 All−−−−
TV F2000 R801 56W/2W 87 A00 665 010 All−−−−
Note :The cement resistor is not installed, if the serial number of unit is not included in−
table above.
If the resistor opens, noises may appear in horizontal directions on screen.
G R Code No. Access Code Modified Ser. No. Parts Schedule
−− − − − −