VESA Mount
A VESA mount feature must be included on the LX1250TI, located on the back cover.
Standard 100 and 75 mm VESA mount M4 x .7 threaded hole pattern. The holes shall be blind.
Additional M4 threaded mounting or cable management locations on rear of display also included to
support vertical cable routing.
See Figure 2: Outline Drawing.
Weight
Weight <5.5lbs.
Shipping Box
Conforms to ISTA-2A (32 inch drop)
Maintenance Requirements/Service Support
Service Requirements
The LX1250TI requires no routine maintenance.
Service BOM
Service BOM provided on request.
Environmental Specifications
Temperature
Operating Temperature -20° C to + 60° C (-4° to 140° F)
Storage Temperature -20° C to + 85° C (-4° to 185° F)
Operating Survival Temp Range -40° C to + 70° C
Humidity
Operating: MIL-STD-810F (95% RH with 20° to 60° C temperature cycle for 11 days)
Altitude
Operating: 15K ft (IEC 60068 PT2-13, 4hr)
Non-operating: 30K ft (IEC 60068 PT2-13, 4 hr)
Vibration
Note: Tests performed with assemblies mounted in a rigid retaining fixture.
Operating ( Random): 10-500 Hz, 3.0G rms acceleration, 3 hours
per axis
Vibration, Endurance Sine Sweep 100-1100 Hz, 4 Gs rms, 1hr/axis
Shock
Note: Tests performed with monitor mounded in a rigid retaining assembly.
Operating/Non-operating: 50 g, 11 ms duration, ½ sine, 3 shocks per axis (IEC 60068 PT2-27)