Sanyo TH3642 / CH3642 Car Speaker User Manual


 
I - 6
SM830082
1
2
3
4
5
1. Specifications
MODEL No. Indoor Unit TH3642
Outdoor Unit CH3642
POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz
PERFORMANCE Cooling Heating
Capacity* BTU / h 34,000 33,000 40,000 39,000
(17°F)** 25,000 24,000
Moisture removal (High) Pints / h 10.7 10.8
Air circulation (H / M / L) 230 V
cu.ft. / min.
1,100 / 930 / 750
S.E.E.R. (H.S.P.F.)
BTU / Wh
10.4 10.7 (7.3) (7.3)
ELECTRICAL RATINGS
Voltage rating VAC 230 208 230 208
Available voltage range VAC 187 - 253
Running amperes A 15.1 15.7 18.2 19.6
Power input* W 3,350 3,170 3,950 3,890
(17°F)** 3,000 2,900
Maximum overcurrent protection A 40
FEATURES
Controls Microprocessor
Low ambient control Built-in 0°F
Fan speeds Indoor / Outdoor 3 and Automatic control / 3 (Auto)
Optional Wired Remote Controller (Timer) RCS-SH80UG (72-hour ON / OFF)
Optional Wireless Remote Controller (Timer) RCS-SH80UA. WL / RCS-BH80UA. WL (72-hour ON / OFF)
Air deflection Horizontal / Vertical Manual / Automatic
Air filter Washable, easy access
Operation sound Indoor - Hi / Me / Lo dB - A 46 / 42 / 37
Outdoor - Hi dB - A 56
Refrigerant control Electronic Expansion Control Valve
REFRIGERANT PIPING
Limit of piping length ft. (m) 165 (50)
Limit of piping length at shipment ft. (m) 100 (30)
Limit of elevation difference ft. (m) Outdoor unit is higher than indoor unit: 165 (50)
between the two units Outdoor unit is lower than indoor unit: 100 (30)
Refrigerant piping Narrow pipe in. (mm) 3 / 8 (9.52)
Flare type Wide pipe in. (mm) 3 / 4 (19.05)
DIMENSIONS & WEIGHT Indoor unit Outdoor unit
Unit dimensions Height in. (mm) 9-7/16 (240) 48-5/8 (1,235)
Width in. (mm) 62-1/32 (1,575) 37-1/32 (940)
Depth in. (mm) 26-3/8 (670) 13-3/8 (340)
Indoor grille dimensions Height in. (mm) 12-15/32 (317) 52-7/32 (1,326)
Width in. (mm) 66-1/16 (1,678) 40 (1,016)
Depth in. (mm) 31-1/16 (789) 16-3/8 (416)
Net weight lbs. (kg) 90 (41) 203 (92)
Shipping weight lbs. (kg) 104 (47) 227 (103)
Shipping volume cu.ft. (m
3
) 14.8 (0.42) 19.8 (0.56)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Cooling :
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating :
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
1-1 Unit Specifications