Sanyo TH3642 / CH3642 Car Speaker User Manual


 
I - 109
SM830082
1
2
3
4
5
1. Specifications
Indoor model: XH4242 / Outdoor model: CH4242
Cooling
Heating
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 V 208 V 230 V 208 V 230 V 208 V 230 V 208 V
Rating conditions
A 1.0 0.9 1.8 1.8 17.8 18.3 20.6 21.0
kW 0.2 0.17 0.36 0.34 3.64 3.58 4.2 4.09
Full load conditions
A 1.0 0.9 1.8 1.8 21.0 21.9 23.8 24.6
kW 0.2 0.17 0.36 0.34 4.41 4.33 4.97 4.84
Starting amperes A 2 2 2 2 131 131 134 133.9
Cooling:
Rating Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB
Outdoor Air Temperature 95 °F DB
Full Load Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB
Outdoor Air Temperature 115 °F DB
Heating:
Rating Conditions : Indoor Air Temperature 70 °F DB / 60 °F WB
Outdoor Air Temperature 47 °F DB / 43 °F WB
Full Load Conditions : Indoor Air Temperature 80 °F DB / — °F WB
Outdoor Air Temperature 45 °F DB / 35 °F WB
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 V 208 V 230 V 208 V 230 V 208 V 230 V 208 V
Rating conditions
A 0.9 0.8 1.8 1.8 18.9 19.6 21.6 22.2
kW 0.19 0.16 0.36 0.34 3.9 3.85 4.45 4.35
Full load conditions
A 0.9 0.8 1.8 1.8 21.2 22.8 23.9 25.4
kW 0.19 0.16 0.36 0.34 4.48 4.52 5.03 5.02
Starting amperes A 2 2 2 2 131 131 133.9 133.8
Electrical characteristics
Electrical Data