Sanyo XH2442 / CH2442 Car Speaker User Manual


 
I - 113
SM830082
1
2
3
4
5
1. Specifications
Cooling:
Rating Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB
Outdoor Air Temperature 95 °F DB
Full Load Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB
Outdoor Air Temperature 115 °F DB
Heating:
Rating Conditions : Indoor Air Temperature 70 °F DB / 60 °F WB
Outdoor Air Temperature 47 °F DB / 43 °F WB
Full Load Conditions : Indoor Air Temperature 80 °F DB / — °F WB
Outdoor Air Temperature 45 °F DB / 35 °F WB
Indoor model: UH2442 / Outdoor model: CH2442
Cooling
Heating
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz
Rating conditions
A 0.9 - 0.8 0.9 - 0.9 9.7 - 10.4 11.5 - 12.1
kW 0.18 - 0.16 0.18 - 0.17 2.19 - 2.15 2.55 - 2.48
Full load conditions
A 0.9 - 0.8 0.9 - 0.9 11.1 - 12 12.9 - 13.7
kW 0.18 - 0.16 0.18 - 0.17 2.53 - 2.48 2.89 - 2.81
Starting amperes A 2 - 2 1 - 1 66 - 60 67.9 - 61.8
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz
Rating conditions
A 0.7 - 0.7 0.9 - 0.9 10.4 - 10.9 12 - 12.5
kW 0.16 - 0.14 0.18 - 0.17 2.31 - 2.24 2.65 - 2.55
Full load conditions
A 0.7 - 0.7 0.9 - 0.9 11.2 - 12.2 12.8 - 13.8
kW 0.16 - 0.14 0.18 - 0.17 2.49 - 2.47 2.83 - 2.8
Starting amperes A 2 - 2 1 - 1 66 - 60 67.7 - 61.7