NSR-1000 Series v1.1.1 Release Note
NTSC
Resolution Maximum frame rate
CIF(352x240) 480
2CIF(704x240) 240
4CIF(704x480) 120
PAL
Resolution Maximum frame rate
CIF(352x288) 400
2CIF(704x288) 200
4CIF(704x576) 100
・ User cannot change parameters about recording settings of analog cameras
in the ‘Schedule Configuration’. Please change setting in ‘Video’ tab on
‘Device Configuration’. These parameters are used as recording settings for
‘Schedule Configuration’.
3-4 Device registration
・ The
camera servers SNT-EX104/EX154/EP104/EP154 can have different IP
addresses by the video channels in it. For this reason, when registering two or
more camera servers by specifying the IP address with the automatic camera
registration or multiple camera registration features, a group of continuous IP
addresses cannot be assigned to the one camera server.
To prevent this, register a camera server one by one, or after specifying the IP
addresses on the camera server in advance, register them with the multiple
camera registration feature without specifying another IP address. (V11R:435)
3-5 Main Window - Search and Play back
・ N/A
3-6 Main Window – Monitoring
・ When
the ‘Configuration Window’ or ‘Search Window’ is opened, the second
display images are stopped. (VT1:1843)