XXV Pellet Stove
Outside air ex pipe
goes here.
Inlet Cover part#
1-10-08542
Flex pipe part#
1-00-08543 (25')

Fig. 7
Fig. 8
Outdoor Half
Indoor Half
Adjustable from 4 1/2" to
10 5/8" wall thickness


T      


 without exhaust blower
operation. Negative pressure in the house will resist this
natural draft if not accounted for in the pellet appliance
installation.
Heat rises in the house and leaks out at upper levels.
This air must be replaced with cold air from outdoors,
which ows into lower levels of the house. Vents and
chimneys into basements and lower levels of the house
can become the conduit for air supply, and reverse
under these conditions.

      
   


Per national building codes, consideration must
be given to combustion air supply to all combustion
appliances. Failure to supply adequate combustion air
for all appliance demands, may lead to back-drafting
of those and other appliances.
When the appliance is side-wall vented: The air
intake is best located on the same exterior wall as the
exhaust vent outlet and located lower on the wall than
the exhaust vent outlet.
When the appliance is roof vented: The air intake is
best located on the exterior wall oriented towards the
prevailing wind direction during the heating season.
The outside air connection will supply the demands of
the pellet appliance, but consideration must be given to
the total house demand. House demand may consume
some air needed for the stove, especially during a power
failure. It may be necessary to add additional ventilation
to the space in which the pellet appliance is located.
Consult with your local HVAC professional to determine
the ventilation demands for your house.
To install outside air use 2 3/8" I.D. non-combustible
ex pipe. There is a break-away hole on the rear panel
of the stove which must be removed to connect the ex
pipe. The maximum length run of this pipe is 15 feet. If
a longer run is needed the size must be increased to
3". Inlet cover part number 1-10-08542 should be used
to keep birds, rodents, etc.out of the pipe unless the
Harman wall passthrough is being used.

The Harman Direct Vent Wall Passthrough (Part
# 1-00-677077) makes installing your Harman Pellet
Stove with outside air easier. It combines the needed
wall protection for the venting, with a source of intake
air for combustion. It is made to t walls from 4 1/2" to
10 1/8" thick with a single square opening in the wall
of 6-1/2 inches.

