11
XXV Pellet Stove
This method provides excellent venting for normal
operation and allows the stove to be installed closest to
the wall. Two inches from the wall is safe; however, four
inches allows better access to remove the rear panel.
The vertical portion of the vent should be three to ve
feet high. This vertical section will help provide natural
draft in the event of a power failure.
This method also provides excellent venting for
normal operation but requires the stove to be installed
farther from the wall. The vertical portion of the vent
should be three to ve feet high and at least three
inches from a combustible wall. This vertical section
will provide natural draft in the event of a power failure.
If the stove is installed below grade be sure the vent
termination is at least 18" above grade. The outlet must
also be 1 foot from the house/building.
Note: Do not place joints within wall pass-
throughs
Fig. 9
to
Combustibles
to Combustibles
Fig. 10
to
Combustibles
to Combustibles
Fig. 11
12" min. wall to outlet
Shaded area represents
the minimum clearance to
combustible materials such as
shrubbery, mulch or tall grasses.